Transparente1
0%
Cargando...

Ammonia solution ROTIPURAN®Supra 20 %

Bs. 91.95Bs. 499.90

Ammonium hydroxide solution, Salmiac solution
Empirical formula NH3 + H2O
Molar mass (M) 17,03 + aq g/mol
Density (D) 0,94 g/cm³
ADR 8 III
WGK 2
CAS No. 1336-21-6
EG-Nr. 215-647-6
UN-Nr. 2672

Highpure alkaline solution (ppb quality) for sample preparation in trace analysis (e.g. using ICP, AAS, Ion chromatography etc.).

N/A
Assay (w/w) 20-22 %
Colour (APHA) ≤10
Chloride (Cl) ≤0,00005 %
Phosphate (PO4) ≤0,000001 %
Sulphate (SO4) ≤0,0001 %
Aluminium (Al) ≤1 ppb
Antimony (Sb) ≤0,5 ppb
Arsenic (As) ≤1 ppb
Barium (Ba) ≤0,1 ppb
Beryllium (Be) ≤0,1 ppb
Lead (Pb) ≤0,1 ppb
Cadmium (Cd) ≤0,5 ppb
Cesium (Cs) ≤0,1 ppb
Calcium (Ca) ≤1 ppb
Cerium (Ce) ≤0,1 ppb
Chromium (Cr) ≤0,5 ppb
Dysprosium (Dy) ≤0,1 ppb
Iron (Fe) ≤1 ppb
Erbium (Er) ≤0,1 ppb
Europium (Eu) ≤0,1 ppb
Gadolinium (Gd) ≤0,1 ppb
Gallium (Ga) ≤0,1 ppb
Germanium (Ge) ≤0,1 ppb
Gold (Au) ≤0,5 ppb
Holmium (Ho) ≤0,1 ppb
Indium (In) ≤0,1 ppb
Potassium (K) ≤1 ppb
Cobalt (Co) ≤0,5 ppb
Copper (Cu) ≤0,5 ppb
Lanthanum (La) ≤0,1 ppb
Lithium (Li) ≤0,1 ppb
Lutetium (Lu) ≤0,1 ppb
Magnesium (Mg) ≤1 ppb
Manganese (Mn) ≤0,5 ppb
Molybdenum (Mo) ≤0,5 ppb
Sodium (Na) ≤1 ppb
Neodymium (Nd) ≤0,1 ppb
Nickel (Ni) ≤0,5 ppb
Niobium (Nb) ≤0,1 ppb
Praseodymium (Pr) ≤0,1 ppb
Mercury (Hg) ≤0,2 ppb
Rhodium (Rh) ≤0,5 ppb
Rubidium (Rb) ≤0,1 ppb
Samarium (Sm) ≤0,1 ppb
Scandium (Sc) ≤0,1 ppb
Selenium (Se) ≤1 ppb
Silver (Ag) ≤0,5 ppb
Strontium (Sr) ≤0,1 ppb
Tellur (Te) ≤0,1 ppb
Terbium (Tb) ≤0,1 ppb
Thallium (Tl) ≤0,1 ppb
Thorium (Th) ≤0,1 ppb
Thulium (Tm) ≤0,1 ppb
Titanium (Ti) ≤0,5 ppb
Uranium (U) ≤0,1 ppb
Vanadium (V) ≤0,5 ppb
Bismuth (Bi) ≤0,1 ppb
Tungsten (W) ≤0,1 ppb
Ytterbium (Yb) ≤0,1 ppb
Yttrium (Y) ≤0,1 ppb
Zinc (Zn) ≤0,5 ppb
Tin (Sn) ≤0,5 ppb
Zirconium (Zr) ≤0,1 ppb

Ammonia solution ROTIPURAN®Supra 20 %

38-430

Damage and burn | Ammonia solution ROTIPURAN®Supra 20 % Examples of effect: Damage metals and burn body tissues; may cause serious eye damage. Safety: Avoid contact; wear safety spectacles and gloves. In the event of contact with eyes and skin, rinse with water.
Damage to heath 1 | Ammonia solution ROTIPURAN®Supra 20 % Examples of effect: Lead to damage to heath, cause irritation to eyes, skin or respiratory organs. Are fatal in larger quantities. Safety: As previously stated, in the event of skin irritation or contact with eyes, rinse with water or a suitable medium.
H290-H314-H335-H412 May be corrosive to metals, causes severe skin burns and eye damage, may cause respiratory irritation, harmful to aquatic life with long lasting effects.
P280 P301+P330+P331 P303+P361+P353 P304+P340 P305+P351+P338 P310 Wear protective clothing/eye protection, IF SWALLOWED: rinse mouth. Do NOT induce vomiting, IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower], IF INHALED: Remove person to fresh air and keep comfortable for breathing, IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing, immediately call a POISON CENTER/doctor.

Description

Ammonia solution ROTIPURAN® Ultra/Supra

Acids, Alkaline Solutions and Water for trace analysis via ICP-OES, ICP-MS, AAS and IC

Carl ROTH provides two high quality product lines, ROTIPURAN® Ultra & Supra specially for research, trace analysis and electronics. These ultrapure reagents are produced using a technologically complex distillation process (subboiling distillation) and are filled only into specially selected, suitable containers under clean room conditions. Very extensive production and quality controls guarantee extremely high quality.

ROTIPURAN® Supra

This supra quality line (ppb-quality) is perfectly suitable for sample preparation in trace analysis (e.g. via ICP-OES, AAS, IC, etc.). Over 60 elements are specified and their content is below 1 ppb [parts per billion =10-9]. Bottled and delivered in special plastic bottles. The certificates of analysis are available online.

Additional information

Pack

Volumen

,