EMC-11S-V+ EMC-λ Lambda PRO , Spectrophotometer, Single Beam,
Bs. 0.00Bs. 0.00
EMC-11S-V+ EMC-λ Lambda PRO, Spectrophotometer, Single Beam
- Color TFT screen
- Self-check system
- Fast choose wavelength
- Auto setting wavelength
- Auto Zero and Blank
- Sample compartment for different cell holders
- Incl. PC software EASY UV BASIC (Quantitative, Kinetics,
- Photometry Measurement)
- Incl. EMCLAB Works Calibration Certificate
Optionally available:
- PC software EASY UV (Quantitative, Kinetics, Wavelength Scan,
- Multi-Wavelength, DNA/Protein, Energy Scan)
- Windows® Pad
- IQ/OQ/PQ documentation
- Audit Trail PC software (FDA 21 CFR part 11 compliant)
Model | EMC-11S-V |
Wavelength Range | 325-1000 nm |
Spectral Bandwidth | 4 nm |
Optical System | Single Beam, grating 1200 lines/mm |
Wavelength Accuracy | ±2 nm |
Wavelength Repeatability | 1 nm |
Photometric Accuracy | ≤±0.5 % T or ±0.004A@1A |
Photometric Range | 0-200 % T, -0.3 – 3A 0-1999 conc. |
Photometric Repeatability | ≤0.2 % T |
Photometric Mode | T, A, C, F |
Stray Light | 0.2 % T |
Stability | ±0.004A/h@500 nm |
Baseline Flatness | ±0.001A (200-1000 nm) |
Noise | 0.003A@500 nm |
Detector | Silicone Photodiode |
Display | Color TFT screen |
Central beam height | 15 mm |
Standard Cell Holder | 4-position cell holder 10×10 mm |
Light Source | Tungsten lamp |
Output | USB port & Parallel port for printer |
Power Requirement | AC 85V~265V 50/60 Hz |
Dimensions (LxWxH) | 440 x 350 x 200 mm |
Weight | 8 kg |
Description
EMC-11S-V+ EMC-λ Lambda PRO , Spectrophotometer, Single Beam, Wavelength 325-1000 nm, Bandwidth 4 nm, incl. 4 glass cells 10×10 mm, PC software EMC-λ Lambda PRO Features: Color TFT screen self-check system fast choose wavelength auto setting wavelength auto zero and blank sample compartment for different cell holders Incl. PC Software EMC-λ Lambda PRO incl. Calibration Certificate Optionally available: Windows® Pad, IQ/OQ/PQ documentation, Audit Trail PC software (FDA 21 CFR part 11 compliant) Model EMC-11S-V + EMC-λ Lambda PRO Wavelength Range 325-1000 nm Spectral Bandwidth 4 nm Optical System Single Beam, grating 1200 lines/mm Wavelength Accuracy ±2 nm Wavelength Repeatability 1 nm Photometric Accuracy ?±0.5 % T or ±0.004A@1A Photometric Range 0-200 % T, -0.3-3A, 0-1999 conc. Photometric Repeatability ?0.2 % T Photometric Mode T, A, C, F Stray Light 0.2 % T Stability ±0.004A/h@500 nm Baseline Flatness ±0.001A (200-1000 nm) Noise 0.003A@500 nm Detector Silicone Photodiode Display TFT color screen Central Beam Height 15 mm Standard Cell Holder 4-position cell holder 10×10 mm Light Source Tungsten lamp Output USB port & Parallel port for printer Power Requirement AC 85V~265V 50/60 Hz Dimensions (LxWxH) 440 x 350 x 200 mm Weight 8 kg Model BASIC PRO / PRO+ Number of Devices / PC 1 Device PRO 1 Device / PRO+ 3 Devices Multi Wavelength Measurement Number of Wavelengths 1 20 Measurements per Task 1 unlimited Tasks per Day 3 unlimited Spectrum Scan Wavelength range Fixed 550 – 750 nm free selection Wavelength interval Fixed 5 nm free selection Measurements per Task 1 unlimited Tasks per Day 3 unlimited Quantitative Measurement Measurements per Task 1 unlimited Tasks per Day 3 unlimited DNA/RNA Predefined Methods 1 2 Definition of own Methods no yes Measurements per Task 1 unlimited Tasks per Day 3 unlimited Kinetic Measurement Fixed start delay 30 s free selection Fixed measurement interval 5 s free selection Fixed total-runtime 60 s free selection Fixed wavelength 550 nm free selection Measurements per Task 1 unlimited Tasks per Day 3 unlimited Selectable Cells 0.5/10/50/100mm yes yes