EMC-NANO-UV , Spectrophotometer, Single Beam

Bs. 0.00Bs. 0.00

EMC-NANO-UV , Spectrophotometer, Single Beam

  • LCD screen (320*240 dots)
  • Self-check system
  • Auto setting wavelength
  • Auto Zero and Blank
  • Unique Flip cell holder 2 in 1 for NANO volume and standard cells 0.2 ~ 2.5 µl sample volume for DNA, RNA, PCR, protein
  • Incl. USB memory stick for methods and results
  • Incl. PC software ANALYST (Quantitative, Kinetics, Photometry Measurement, Wavelength Scan, Multi-Wavelength, DNA/Protein, System Utilities)
  • Incl. EMCLAB Works Calibration Certificate

 

Optionally available:

  • Windows® Pad
  • IQ/OQ/PQ documentation
  • Audit Trail PC software (FDA 21 CFR part 11 compliant)

The unique Flip cell holder for NANO volume and standard cells:

  • Simple to use
  • NANO cell holder optical path length 0.5 mm
  • Cell holder for standard cells optical path length 10 mm
  • Horizontal light path – high precision – no loss of energy
Model EMC-NANO-UV
Wavelength Range 190-1100 nm
Spectral Bandwidth 4 nm
Optical System Single Beam, grating 1200 lines/mm
Wavelength Accuracy ±0.5 nm
Wavelength Repeatability 0.3 nm
Photometric Accuracy ≤0.5 % T or ±0.004A@1A
Photometric Repeatibility ≤0.001A (0-0.5A), ≤0.002A (0-0.5A) ≤0.5 % T (0-100%)
Photometric Range 0-200 % T, -0.3 – 3A, 0-9999 Conc.
Scan Speed Hi, MED, LOW – MAX: 3000nm/min
Stray Light 0.05 % T@220, 340 nm
Stability ±0.002A/h@500 nm
Baseline Flatness ±0.002A (200-1000 nm)
Noise 0.0005A@500 nm
Detector Silicone Photodiode
Display LCD 320*240 dots
Central beam height 15 mm
Flip Cell Holder 0.2~2.5 µl and cell 10 mm path length
Light Source Tungsten & Deuterium lamp
USB port A for USB memory stick USB port B for PC connectivity
Parallel port for printer Power Requirement
Output AC 110/230V 50/60 Hz
Dimensions (LxWxH) 490 x 370 x 220 mm
Weight 14 kg

Description

EMC-NANO-UV , Spectrophotometer, Single Beam

EMC-NANO-UV , Spectrophotometer, Single Beam, Minimum sample size 0.2-2.5 µl, Wavelength 190-1100nm, Bandwidth 4nm, PC software ANALYST Features: Single Beam 0.2 ~ 2.5 ?l sample volume for DNA, RNA, PCR, protein LCD screen (320*240 dots) Self-check system Auto setting wavelength Auto Zero and Blank Sample compartment for different cell holders Unique Flip cell holder 2 in 1 for NANO volume and standard cells Incl. USB memory stick for methods and results Incl. PC Software ANALYST (Quantitative, Kinetics, Photometry Measurement, Wavelength Scan, Multi-Wavelength, DNA/Protein, System Utilities) Incl. EMCLAB Calibration Certificate Model EMC-NANO-UV Wavelength Range 190-1100 nm Spectral Bandwidth 4 nm Optical System Single Beam, grating 1200 lines/mm Wavelength Accuracy ±0.5 nm Wavelength Repeatability 0.3 nm Photometric Accuracy ?±0.5 % T or ±0.004A@1A Photometric Range 0-200 % T, -0.3 – 3A, 0-9999 Conc. Photometric Repeatability ?0.001A (0-0.5A), ?0.002A (0-0.5A), ?0.5 % T (0-100%) Scan Speed Hi, MED, LOW – MAX: 3000 nm/min Stray Light 0.05 % T@220, 340 nm Stability ±0.002A/h@500 nm Baseline Flatness ±0.002A (200-1000 nm) Noise 0.0005A@500 nm Detector Silicone Photodiode Display LCD 320*240 dots Central Beam Height 15 mm Flip Cell Holder 0.2~2.5 µl and cell 10 mm path length Light Source Tungsten & Deuterium lamp Output USB port A for USB memory stick USB port B for PC connection Parallel port for printer Power Requirement AC 110/230 V 50/60 Hz Dimensions (LxWxH) 490 x 370 x 220 mm Weight 14 kg