High Temperature Laboratory Oven – LHT
Bs. 0.00Bs. 0.00
High Temperature Laboratory Oven – LHT
Please note
– *Recovery to 500°C set-point
– The uniform volume is smaller than the total chamber volume
– Maximum power and heat up times based on a 240V supply
Content may be subject to modifications or corrections
Options (specify these at time of order)
- A range of sophisticated digital controllers, multisegment programmers and data loggers with digital communication options is available – more information about controllers
- Cable entry ports
- Over-temperature protection (recommended to protect valuable contents & for unattended operation)
- Viewing window
- Variable speed fan
- Floor stands & stacking frames with vent
- Routine spares kit
- Air exhaust fan (may alter achievable uniformity)
- Heavy duty reinforced base and shelves
LHT 4/30
Max temp (°C) | 400 |
Min temp (°C) | Ambient +60 |
Volume (litres) | 30 |
Temp stability (°C) | ±0.5 |
Temp uniformity (°C) | ±5.0 @ 250°C |
Heat-up time (mins) | 50 |
Recovery time (mins) | 10 |
Dimensions: Internal H x W x D (mm) |
300 x 300 x 305 |
Dimensions: External H x W x D (mm) |
570 x 860 x 550 |
Shelves fitted / accepted | 2 |
Shelf loading each / total (kg) | 10 / 20 |
Optional heavy duty reinforced base max. weight (kg) | 40 |
Optional heavy duty shelves max. quantity | 2 |
Optional heavy duty shelves max. weight / shelf (kg) | 20 |
Max power (W) | 1000 |
Weight (kg) | 73 |
LHT 4/60
Max temp (°C) | 400 |
Min temp (°C) | Ambient +60 |
Volume (litres) | 60 |
Temp stability (°C) | ±0.5 |
Temp uniformity (°C) | ±5.0 @ 250°C |
Heat-up time (mins) | — |
Recovery time (mins) | 16 |
Dimensions: Internal H x W x D (mm) |
400 x 400 x 405 |
Dimensions: External H x W x D (mm) |
670 x 930 x 670 |
Shelves fitted / accepted | 2 / 3 |
Shelf loading each / total (kg) | 15 / 30 |
Optional heavy duty reinforced base max. weight (kg) | 60 |
Optional heavy duty shelves max. quantity | 3 |
Optional heavy duty shelves max. weight / shelf (kg) | 20 |
Max power (W) | 1500 |
Weight (kg) | 99 |
LHT 4/120
Max temp (°C) | 400 |
Min temp (°C) | Ambient +60 |
Volume (litres) | 120 |
Temp stability (°C) | ±0.5 |
Temp uniformity (°C) | ±5.0 @ 250°C |
Heat-up time (mins) | — |
Recovery time (mins) | 20 |
Dimensions: Internal H x W x D (mm) |
645 x 455 x 405 |
Dimensions: External H x W x D (mm) |
920 x 1060 x 670 |
Shelves fitted / accepted | 2 / 4 |
Shelf loading each / total (kg) | 15 / 40 |
Optional heavy duty reinforced base max. weight (kg) | 80 |
Optional heavy duty shelves max. quantity | 3 |
Optional heavy duty shelves max. weight / shelf (kg) | 25 |
Max power (W) | 2250 |
Weight (kg) | 137 |
LHT 5/30
Max temp (°C) | 500 |
Min temp (°C) | Ambient +60 |
Volume (litres) | 30 |
Temp stability (°C) | ±0.5 |
Temp uniformity (°C) | ±5.0 @ 250°C |
Heat-up time (mins) | — |
Recovery time (mins) | 10 |
Dimensions: Internal H x W x D (mm) |
300 x 300 x 305 |
Dimensions: External H x W x D (mm) |
570 x 860 x 550 |
Shelves fitted / accepted | 2 |
Shelf loading each / total (kg) | 10 / 20 |
Optional heavy duty reinforced base max. weight (kg) | 40 |
Optional heavy duty shelves max. quantity | 2 |
Optional heavy duty shelves max. weight / shelf (kg) | 20 |
Max power (W) | 2000 |
Weight (kg) | 73 |
LHT 5/60
Max temp (°C) | 500 |
Min temp (°C) | Ambient +60 |
Volume (litres) | 60 |
Temp stability (°C) | ±0.5 |
Temp uniformity (°C) | ±5.0 @ 250°C |
Heat-up time (mins) | 50 |
Recovery time (mins) | 16 |
Dimensions: Internal H x W x D (mm) |
400 x 400 x 405 |
Dimensions: External H x W x D (mm) |
670 x 930 x 670 |
Shelves fitted / accepted | 2 / 3 |
Shelf loading each / total (kg) | 15 / 30 |
Optional heavy duty reinforced base max. weight (kg) | 60 |
Optional heavy duty shelves max. quantity | 3 |
Optional heavy duty shelves max. weight / shelf (kg) | 20 |
Max power (W) | 2250 |
Weight (kg) | 99 |
LHT 5/120
Max temp (°C) | 500 |
Min temp (°C) | Ambient +60 |
Volume (litres) | 120 |
Temp stability (°C) | ±0.5 |
Temp uniformity (°C) | ±5.0 @ 250°C |
Heat-up time (mins) | — |
Recovery time (mins) | 20 |
Dimensions: Internal H x W x D (mm) |
645 x 455 x 405 |
Dimensions: External H x W x D (mm) |
920 x 1060 x 670 |
Shelves fitted / accepted | 2 / 4 |
Shelf loading each / total (kg) | 15 / 40 |
Optional heavy duty reinforced base max. weight (kg) | 80 |
Optional heavy duty shelves max. quantity | 3 |
Optional heavy duty shelves max. weight / shelf (kg) | 25 |
Max power (W) | 3000 |
Weight (kg) | 137 |
LHT 6/30
Max temp (°C) | 600 |
Min temp (°C) | Ambient +60 |
Volume (litres) | 30 |
Temp stability (°C) | ±0.5 |
Temp uniformity (°C) | ±5.0 @ 250°C |
Heat-up time (mins) | 70 |
Recovery time (mins) | 10 |
Dimensions: Internal H x W x D (mm) |
300 x 300 x 305 |
Dimensions: External H x W x D (mm) |
570 x 860 x 550 |
Shelves fitted / accepted | 2 |
Shelf loading each / total (kg) | 10 / 20 |
Optional heavy duty reinforced base max. weight (kg) | 40 |
Optional heavy duty shelves max. quantity | 2 |
Optional heavy duty shelves max. weight / shelf (kg) | 20 |
Max power (W) | 2000 |
Weight (kg) | 73 |
LHT 6/60
Max temp (°C) | 600 |
Min temp (°C) | Ambient +60 |
Volume (litres) | 60 |
Temp stability (°C) | ±0.5 |
Temp uniformity (°C) | ±5.0 @ 250°C |
Heat-up time (mins) | — |
Recovery time (mins) | 10* |
Dimensions: Internal H x W x D (mm) |
400 x 400 x 405 |
Dimensions: External H x W x D (mm) |
670 x 930 x 670 |
Shelves fitted / accepted | 2 / 3 |
Shelf loading each / total (kg) | 15 / 30 |
Optional heavy duty reinforced base max. weight (kg) | 60 |
Optional heavy duty shelves max. quantity | 3 |
Optional heavy duty shelves max. weight / shelf (kg) | 20 |
Max power (W) | 2250 |
Weight (kg) | 99 |
LHT 6/120
Max temp (°C) | 600 |
Min temp (°C) | Ambient +60 |
Volume (litres) | 120 |
Temp stability (°C) | ±0.5 |
Temp uniformity (°C) | ±5.0 @ 250°C |
Heat-up time (mins) | — |
Recovery time (mins) | — |
Dimensions: Internal H x W x D (mm) |
645 x 455 x 405 |
Dimensions: External H x W x D (mm) |
920 x 1060 x 670 |
Shelves fitted / accepted | 2 / 4 |
Shelf loading each / total (kg) | 15 / 40 |
Optional heavy duty reinforced base max. weight (kg) | 80 |
Optional heavy duty shelves max. quantity | 3 |
Optional heavy duty shelves max. weight / shelf (kg) | 25 |
Max power (W) | 3000 |
Weight (kg) | 137 |
Description
High Temperature Laboratory Oven – LHT
The high temperature laboratory oven range LHT comprise three sizes of bench mounted units, each available with maximum operating temperatures of 400°C, 500°C and 600°C.
Standard features
- 400°C, 500°C or 600°C maximum operating temperatures
- 30, 60 & 120 litre capacities
- R38 PID controller
- Heavy duty convection fan for good uniformity
- Low thermal mass insulation for fast response & energy efficiency
- Corrosion resistant, brushed stainless steel interior
- 2 Multi-position shelves
- Suitable for continuous operation
- Hard wearing, zinc coated & stoved epoxy polyester coated exterior