Scan 4000

Bs. 0.00Bs. 0.00

Scan 4000

  • Inhibition zone measurement accuracy: ± 0.2 mm
  • Fast: up to 16 inhibition zones in 2 to 4 seconds
  • Protocols: wells, peni-cylinders, paper disks
  • Interpretation systems: EUCAST, CA-SFM, CLSI and customizable
  • Automatic colony counting

Applications

Scan 4000 makes it possible to check the effectiveness of an antibiotic on a microorganism by measuring the zone of inhibition. In addition, it adapts to perform titration and/or antibiotic dosage in the pharmaceutical industry. In the field of animal health, the Scan evaluates antimicrobial resistance with its SIR interpretation.

Pharmaceutical Veterinary
https://www.interscience.com/IMG/gif/paperdisc_muellerhinton_120_beforeafter_480-min.gif

Quick results

Scan 4000 reads up to 16 antibiotics on a Petri dish in just 2-4 seconds.

The result is categorized SIR:

Green: susceptible
Yellow: intermediate
Red: resistant


Pills on Mueller Hinton before/after reading

Detection on all Petri dishes

Scan 4000 automatically detects the peni-cylinders, present or removed, made of steel or plastic. It also reads agar wells or paper disks (any brand). Add/remove disks manually.The inhibition zones can also be resized. Scan 4000 allows reading on blood, chocolate or Mueller Hinton agar. In its automatic colony counter mode, Scan 4000 counts colonies on round or square Petri dishes.

 

COUNTING
https://www.interscience.com/IMG/png/masse-surface.png https://www.interscience.com/IMG/png/denombrement-lecture_spiral.png https://www.interscience.com/IMG/png/denombrement-lecture_membrane-de-filtration.png
Pour and surface Spiral Filtration membrane
INHIBITION ZONE READING
https://www.interscience.com/IMG/png/denombrement-lecture_90mm.png https://www.interscience.com/IMG/png/denombrement-lecture_carree120mm.png https://www.interscience.com/IMG/png/peni-cylindres_tsa-min.png https://www.interscience.com/IMG/png/peni-cylindres_retires_tsa-min.png https://www.interscience.com/IMG/png/puits_tsa-min.png https://www.interscience.com/IMG/png/pastilles_gelosesang-min.png https://www.interscience.com/IMG/png/pastilles_muellerhinton-min.png
Ø 90 mm – Ø 150 mm Square 120 mm Peni-cylinders
on TSA agar
Removed peni-cylinders
on TSA agar
Agar wells
on TSA
Paper disks
on blood agar
Paper disks
on Mueller Hinton agar

21 CFR Part 11 included

The Scan software complies with FDA recommendations,
particularly on audit trail and security of results.
The user account management, integrated in the software,
allows the creation of up to 5 levels of rights. The Supervisor-Administrator has all the roles while the other roles are subject to certain rights. Password management secures user accounts.

https://www.interscience.com/IMG/png/picto-21cfr_100.png

https://www.interscience.com/IMG/jpg/scan4000_computer_21cfrpart11_600-min.jpg

Traceability

https://www.interscience.com/IMG/png/tracabilite_connexion_lims-min.png https://www.interscience.com/IMG/png/tracabilite_codebarres-min.png https://www.interscience.com/IMG/png/tracabilite_datalink-min.png
Data Import
SIL/LIMS connection Bar-code dataLink

Scan 4000 connects to the LIMS in bi-directionality and can be connected to the diluter and plater via dataLink traceability system.

Data Export

Scan 4000 offers multiple export possibilities to save manual input time. It also increases the security and quality of your analyses.

Usually, Petri dishes are thrown away after counting and no further verification is possible in the event of a claim. With Scan 4000, all reports are archived.

Export your results to your PC or archive them in CSV, ExcelTM, OpenOfficeTM, PDF, SCA, BIO format. You can also export images from the camera in JPEG, PNG and BMP format.

https://www.interscience.com/IMG/png/tracabilite_connexion_lims-min.png https://www.interscience.com/IMG/png/tracabilite_21cfr-min.png https://www.interscience.com/IMG/png/tracabilite_sauvegarde-min.png https://www.interscience.com/IMG/png/tracabilite_pdf-min.png https://www.interscience.com/IMG/png/tracabilite_jpg-min.png https://www.interscience.com/IMG/png/tracabilite_excel-min.png https://www.interscience.com/IMG/png/tracabilite_csv-min.png
SIL/LIMS connection Audit trail Backup and archive sessions PDF JPG, PNG, BMP ExcelTM OpenOfficeTM CSV

Printed results

All data, images, photos and results
are exportable in printed reports, sca, pdf, jpg, xls, csv.

Scan 4000 ZI rapport imprimé EN

https://www.interscience.com/IMG/png/logo-sfm_2.png

https://www.interscience.com/IMG/png/clsi_logo.pnghttps://www.interscience.com/IMG/png/eucast_logo_cmjn_2.png

Integrated databases

The Scan software is equipped with a
database of antibiotics from the French Society
of Microbiology (CA-SFM 2020), the European
Committee of Antibiograms (EUCAST 2020),
the Clinical and Laboratory Standards Institute (CLSI). This database can be modified by the user.

 

 

 

 

Warranty

Scan 4000 inhibition zone readers have 3-YEAR warranty
(parts and labour) just by sending the warranty card back.

3 year warranty

Description

Scan 4000

Ultra HD inhibition zone reader

State-of-the-art technology

 

Scan 4000 is an ultra HD inhibition zone reader. It has been designed for the pharmaceutical industries, medical research and animal health. It reads 120 mm square dishes 120 mm and round dishes up to 150 mm. Scan 4000 also counts colonies on Petri dishes.